2024_11_13_Photo3.jpg

Richard Alex Jenkins

Transcription Example


Including timestamps to the millisecond.


The first two minutes are shown in this example.


Audio transcriptions are in .SRT or .VTT formats.


00:00:07,000 --> 00:00:10,500

Today we'll be reviewing the GSI Audera Pro ABR module.


00:00:12,000 --> 00:00:18,000

The Evoked Potential module includes a

variety of Evoked Potential test types


00:00:18,100 --> 00:00:23,500

including ECOG, ABR, MLR, P300, etc.


00:00:23,600 --> 00:00:28,500

There are multiple protocols for each test type

that are included with the software.


00:00:28,600 --> 00:00:32,500

The parameters used with these protocols

are those most commonly used.


00:00:32,700 --> 00:00:39,500

We also include normative data for infants and adults,

and a variety of test stimuli that include:


00:00:39,600 --> 00:00:45,500

CE-Chirp, CE-Chirp Octave Bands, Clicks

and Tonebursts, and speech stimuli.


00:00:46,900 --> 00:00:55,500

To set up the Audera Pro hardware, you simply

need a USB cable that connects to the computer.


00:00:56,200 --> 00:01:01,500

Air-conduction transducers - the inserts are pictured here -

but we also provide the headphones.


00:01:02,000 --> 00:01:09,500

Bone oscillator, and you would have to decide which

patient cable you were going to use for the test


00:01:09,600 --> 00:01:11,500

you were going to complete.


00:01:12,000 --> 00:01:16,000

To set everything up, you want

to plug the device into power


00:01:16,100 --> 00:01:21,500

and you want to make sure that you plug

directly into a wall unit, not a power strip.


00:01:21,700 --> 00:01:25,300

Make sure that the wall unit is earth grounded.


00:01:25,500 --> 00:01:27,700

The USB cable will plug in here.


00:01:28,000 --> 00:01:36,000

If you have an OAE module as well as the EP module,

the probe would plug into the HDMI connector.


00:01:37,800 --> 00:01:43,300

One set of air-conduction transducers can be connected at a time.


00:01:43,400 --> 00:01:48,000

So, in this case, we would be using

the insert earphones pictured here.


00:01:48,100 --> 00:01:55,000

If you're going to perform bone conduction,

ABR, the oscillator - B81 oscillator -


00:01:55,100 --> 00:02:00,500

would plug into the bone conduction port,

and then the patient cable would be plugged in here.